183
SAM7S Series [DATASHEET]
6175M–ATARM–26-Oct-12
23.8.15
AIC Spurious Interrupt Vector Register
Register Name:
AIC_SPU
Access Type:
Read/Write
Reset Value:
0x0
SIVR: Spurious Interrupt Vector Register
The user may store the address of a spurious interrupt handler in this register. The written value is returned in AIC_IVR in
case of a spurious interrupt and in AIC_FVR in case of a spurious fast interrupt.
23.8.16
AIC Debug Control Register
Register Name:
AIC_DEBUG
Access Type:
Read/Write
Reset Value:
0x0
PROT: Protection Mode
0 = The Protection Mode is disabled.
1 = The Protection Mode is enabled.
GMSK: General Mask
0 = The nIRQ and nFIQ lines are normally controlled by the AIC.
1 = The nIRQ and nFIQ lines are tied to their inactive state.
31
30
29
28
27
26
25
24
SIVR
23
22
21
20
19
18
17
16
SIVR
15
14
13
12
11
10
9
8
SIVR
76
543210
SIVR
31
30
29
28
27
26
25
24
––
––––––
23
22
21
20
19
18
17
16
––
––––––
15
14
13
12
11
10
9
8
––
––––––
76
543210
––
––––
GMSK
PROT